Double Air Head - Two Stage Gas Boosters
For the greatest combination of pressure and compression ratios the double acting– two stage – double air head models are ideal. There are four double air head – two stage boosters, DLE5-30-2 Gas Booster, DLE15-30-2 Gas Booster, DLE15-75-2 Gas Booster and DLE30-75-2 Gas Booster. These boosters provide maximum flow in low air drive and gas supply pressure conditions.
For high pressure applications or where air drive pressure is low High Pressure Technologies offers three double acting – single stage boosters with a double air head. These models include the DLE15-2 Gas Booster, DLE30-2 Gas Booster and DLE75-2 Gas Booster.
Styles | Model | Ratio | Supply Pressure | Outlet
Pressure |
Stall
Pressure |
Max
Cycle |
Displacement
Per Cycle |
||
Minimum | Maximum | ||||||||
Double Acting, Two Stage, Double Air Head |
DLE2-5-2 | 10:1 | 0 psi | 1.6 x Pa | 1,450 psi | 10Pa + 2.5Ps | 90 | 56.2 cu in | |
DLE5-15-2 | 30:1 | 30 psi | 3.2 x Pa | 4,350 psi | 30Pa + 3Ps | 100 | 22.7 cu in | ||
DLE5-30-2 | 60:1 | 30 psi | 1.0 x Pa | 8,700 psi | 60Pa + 6Ps | 100 | 22.7 cu in | ||
DLE15-30-2 | 60:1 | 100 psi | 15.0 x Pa | 8,700 psi | 60Pa + 2Ps | 100 | 7.4 cu in | ||
DLE15-75-2 | 150:1 | 100 psi | 5.0 x Pa | 21,750 psi | 150Pa +5Ps | 100 | 7.4 cu in | ||
DLE30-75-2 | 150:1 | 220 psi | 24.0 x Pa | 21,750 psi | 150Pa + 2.5Ps | 110 | 3.6 cu in | ||
DLE30-75-2-25 | 150:1 | 220 psi | 24.0 x Pa | 25,000 psi | 150Pa + 2.5Ps | 110 | 3.6 cu in | ||
DLE30-75-2-30 | 150:1 | 220 psi | 40.0 x Pa | 30,000 psi | 150Pa + 2.5Ps | 100 | 3.6 cu in |