L-D Series High Pressure Pumps
The L-D Series are double-acting pumps. These pumps are double-acting versions of Maximator’s L-series pumps, which are also known as workhorse series.
- L-D Series double-acting pumps have stainless steel bodies, and plungers, which have UHMWPE (Ultra High Molecular Weight Polyethylene) seals. Also, these pumps have Viton 2 O-rings (-VE).
- The pumps from L-60DS to L250DS are available with side inlet.
- Maximum air drive pressure of these pumps is 145 psi.
- Minimum air drive pressure of these pumps is 15 psi.
- ACP must be added to catalog number for pumps with air control version.
- All L-D pumps are provided with an unregulated pilot port, 1/8″FNPT. This feature is standard, and allows easy on/off pump control using a pilot switch, or a small valve.
- These pumps produce less pulsation, and deliver more than 50% flow.
- All L-D pumps have single head style, and are available in 8 pressure ratios.
Technical Data
CATALOG |
PRESSURE |
MAXIMUM OUTLET |
DISPL . PER CYCLE (IN.3)
|
CONNECTIONS
|
WEIGHT (LBS)
|
|
INLET
|
OUTLET
|
|||||
L10D-VE | 1:10 | 1,450 | 10.98 | 1 | 1/2 | 48 |
L15D-VE | 1:15 | 2,175 | 7.56 | 1 | 1/2 | 48 |
L25D-VE | 1:27 | 3,915 | 4.31 | 1/2 | 1/2 | 42 |
L35D-VE | 1:40 | 5,800 | 2.98 | 1/2 | 1/2 | 42 |
L60DS-VE | 1:63 | 9,135 | 1.92 | 1/2 | 1/2 | 37 |
L100DS-VE | 1:113 | 15,225 | 1.07 | 1/2 | 1/2 | 37 |
L150DS-VE | 1:151 | 21,025 | 0.80 | 1/2 | 9/16–18 | 37 |
L250DS-VE | 1:265 | 38,425 | 0.46 | 1/2 | 9/16–18 | 37 |
Note: All L-D pumps have 1/2″ FNPT air drive inlet connection.
Maximum allowable liquid temperature is 140°F.
Air section temperature rating is 0°F – 140°F.
Air pilot connection measures 1/8”, and is essential for operation.
The 9 /16″ –18 is a 1/4″ O.D. tubing, threaded, and high pressure coned connection.
2 Viton is a trademark of E.I. DuPont de Nemours & Co., Inc.
Maximum allowable liquid temperature is 140°F.
Air section temperature rating is 0°F – 140°F.
Air pilot connection measures 1/8”, and is essential for operation.
The 9 /16″ –18 is a 1/4″ O.D. tubing, threaded, and high pressure coned connection.
2 Viton is a trademark of E.I. DuPont de Nemours & Co., Inc.
CATALOG |
SAMPLE |
OUTLET PRESSURE (PSI)
|
|||||||||||
0
|
500
|
1000
|
1500
|
2000
|
3000
|
4000
|
5000
|
7500
|
10000
|
15000
|
|||
L10D-VE
|
60
90 |
1700
1750 |
650
1200 |
||||||||||
L15D-VE
|
60
90 |
1150
1200 |
775
1000 |
550
|
|||||||||
L25D-VE
|
60
90 |
660
680 |
580
630 |
385
540 |
120
220 |
220
|
|||||||
L35D-VE
|
60
90 |
460
460 |
420
450 |
350
415 |
250
370 |
140
300 |
140
|
||||||
L60D-VE
|
60
90 |
300
300 |
285
290 |
260
285 |
230
270 |
190
250 |
100
200 |
135
|
|||||
L100D-VE
|
60
90 |
165
165 |
162
163 |
155
161 |
150
160 |
140
157 |
120
134 |
97
132 |
65
120 |
69
|
|||
L150D-VE
|
60
90 |
125
125 |
123
124 |
120
123 |
116
122 |
113
121 |
103
117 |
90
110 |
77
103 |
32
76 |
50
|
||
L250D-VE
|
60
90 |
70
72 |
69
71 |
68
70 |
67
69 |
66
68 |
63
67 |
62
66 |
60
66 |
50
62 |
38
56 |
7
38 |
FLOW RATE IN CUBIC INCHES PER MINUTE.
MAXIMUM AIR CONSUMPTION: 55 SCFM @ 90 PSI (WITH 0 PSI OUTLET).
FLOW RATES SHOWN ARE FOR 1-10 CST FLUIDS.