PP-Series High Pressure Pumps
Maximator PP Series Air Driven High Pressure pumps are compact, lightweight and feature rugged construction capable to increase pressures from 60 to 58,000 psi.
They are available as single acting with either single or double air drive heads and double acting with single air drive head.
- PP4 through PP12 pumps have anodized aluminum bodies and stainless steel plungers. PP22 through PP189 have stainless steel bodies and plungers. All PP pumps have polyurethane seals with Buna “N” O-rings.
- All PP series pumps are standard with a bottom inlet. For a side inlet, add – S to the catalog number.
- Maximum air drive pressure is 145 psi. These pumps require less drive pressure because the pumps are air driven in both directions with no spring under the piston. This design reduces noise and provides less chance of cavitation.
- Minimum air drive pressure 15 psi.
- For air control option … add – ACM to catalog number.
- PP111 and PP189 pumps are available with a double air drive head. This doubles the effective pressure ratio of the pump providing higher pressure capabilities, or using less air pressure to achieve a given outlet pressure. Add -2 to the catalog number.
- The PP22 through PP189 are available with a hand lever …add – HL to the catalog number. With the hand lever option,the pump can be operated manually or with air.
Single Air Drive Head
|
Single, Double and Triple Air Drive Head
|
|||||||||||||||||||||||
|
|
Technical Data
-
CATALOG
NUMBERPRESSURE
RATIOMAXIMUM OUTLET
PRESSURE
(PSI)DISPL . PER CYCLE (IN.3)CONNECTIONSWEIGHT (LBS)INLETOUTLETPP4 1:4 580 1.86 1 1/2 7 PP8 1:9 1,305 0.90 3/4 1/2 7 PP12 1:14 2,030 0.57 3/4 1/2 7 PP22 1:28 4,060 0.28 3/8 1/4 7 PP37 1:46 6,670 0.17 3/8 1/4 7 PP72 1:86 12,470 0.09 3/8 1/4 7 PP111 1:130 15,000 0.06 3/8 1/4 7 PP189 1:220 31,900 0.04 3/8 9/16-18 7 NOTE: Air drive inlet connection on all PPO pumps is 1/4″ FNPT.
All connections listed are FNPT unless otherwise noted.
Maximum allowable oil temperature is 140°F.
Air section temperature rating: 0°F to 140°F.
-
CATALOG
NUMBERPRESSURE
RATIOMAXIMUM OUTLET
PRESSURE
(PSI)DISPL . PER CYCLE (IN.3)CONNECTIONSWEIGHT (LBS)INLETOUTLETPP111-2 1:260 36,250 0.06 3/8 9/16-18 9 PP189-2 1:440 58,000 0.04 3/8 9/16-18 9 NOTE: Air drive inlet connection on all PP pumps is 1/4″ FNPT.
All connections listed are FNPT unless otherwise noted.
The 9 /16″ –18 is a 1/4″ O.D. tubing, high pressure coned and threaded connection.
Maximum allowable oil/water temperature is 140°F.
Air section temperature rating: 0°F to 140°F.
CATALOG |
SAMPLE |
OUTLET PRESSURE (PSI) Above 35,000 psi for intermittent duty only
|
|||||||||||
0
|
500
|
1500
|
3000
|
5000
|
7500
|
10000
|
15000
|
25000
|
40000
|
55000
|
|||
PP4
|
60
90 120 |
885
905 915 |
50 |
||||||||||
PP8
|
60
90 120 |
422
430 433 |
50
240 325 |
||||||||||
PP12
|
60
90 120 |
272
275 280 |
160
218 245 |
53 |
|||||||||
PP22
|
60
90 120 |
132
136 138 |
110
126 132 |
22
82 105 |
30 |
||||||||
PP37
|
60
90 120 |
81
83 85 |
74
80 82 |
47
68 75 |
37
56 |
15 |
|||||||
PP72
|
60
90 120 |
43
44 45 |
42
43 45 |
37
41 43 |
22
36 39 |
3
24 33 |
3
21 |
4 |
|||||
PP111
|
60
90 120 |
28
29 30 |
27
28 29 |
26
27 28 |
20
26 27 |
12
22 25 |
2
16 21 |
8
16 |
3 |
||||
PP189
|
60
90 120 |
17
17 17 |
15
17 17 |
14
17 17 |
13
16 16 |
12
15 15 |
9
12 14 |
5
11 13 |
6
11 |
4 |
|||
PP111-2
|
60
90 120 |
21
21 22 |
20
21 22 |
20
20 21 |
20
20 21 |
19
19 20 |
16
17 19 |
15
16 18 |
9
12 16 |
7 |
|||
PP189-2
|
60
90 120 |
12
12 13 |
12
12 12 |
12
12 12 |
11
12 12 |
11
12 12 |
10
11 12 |
10
11 12 |
7
10 11 |
1
7 9 |
5 |
1 |
|
PP111-3
|
60
90 120 |
18
19 19 |
18
19 19 |
18
19 19 |
17
18 19 |
17
18 19 |
15
16 17 |
14
16 18 |
10
14 17 |
8
13 |
|||
PP189-3
|
60
90 120 |
11
11 11 |
11
11 11 |
11
11 11 |
10
11 11 |
10
11 11 |
10
11 11 |
9
10 11 |
9
10 11 |
6
8 10 |
5
8 |
5 |
FLOW RATES SHOWN ARE FOR 1-10 CST FLUIDS
FLOW RATE IN CUBIC INCHES PER MINUTE.
MAXIMUM AIR CONSUMPTION FOR “PP” PUMPS: 20 SCFM @ 90 PSI (WITH 0 PSI OUTLET).