DLE5-15-2 Air Driven Gas Booster
Maximator Air Driven Gas Boosters for boosting Nitrogen, Oxygen, Helium, Hydrogen etc
Technical Data
Air Drive Dressure pL: | 1-10 bar / 14.5 – 145psi |
Pressure Ratio i: | 1:4 / 1:10 |
Compression Ratio | 1:25 |
Stage Pressure Ratio | 1:2.5 |
Minimum Suction Pressure pA: | 0 |
Maximum Suction Pressure pA: | 1.6 air drive pressure |
Maximum Outlet Pressure pB: | 100 bar |
Displacement Volume/Double Stroke: | 922 cm³ |
Maximum Cycles: | 90 / min |
Stall Pressure: | PB = 10 * pL + 2.5*pA |
Air Drive Port | 1/2″ NPTF |
Connection Inlet Port | 3/8″ NPT |
Connection Outlet Port | 1/4″ NPT |
Pilot Port | 1/8″ NPT |
Maximum Operating Tempreature | 60 °C |
Net Weight: | 25 kg |
Length: | 776 mm |
Width: | 233 mm |
Height: | 233.50 mm |
For Complete Product Information Visit or Download PDF. DLE 5-15-2 Gas Booster
- Pressures to 30,000 for most gases and 5,000 for oxygen
- Easy to install and operate
- Compact, lightweight design
- Single or double acting and two stage models
- Double air head available in single and two stage boosters
- No electrical power required
- Requires no lubrication
- Boosters are contaminant free
- Units can be operated in series or parallel
- Variety of pressure and compression ratios available
- High pressure gas testing or process qualification
- Charging of accumulators
- Boosting gas pressures from nitrogen or Oxygen bottles and generators
- Nitrogen injection for molding machines
- Leak detection systems
- pressure autoclaving
- Typical Gases – air, nitrogen, helium, oxygen, carbon dioxide, nitrous oxide, neon, argon, hydrogen, carbon monoxide, methane, ethylene and natural gas
All gas boosters are available with an optional air control unit (-ACP). This package is shown below and consists of an air filter, regulator with gauge, shutoff valve and necessary fittings and hose for plumbing unregulated pilot port
HPT offers a wide variety of other accessories to assist the installation of your Maximator gas booster.
- Gas receivers
- Pressure gauges
- Air pilot pressure switches
- Filters
- High pressure valves, fittings and tubing
- Miscellaneous plumbing components
* = Minimum required for basic operation
** = Minimum required to achieve maximum outlet pressures
Pa = Drive air pressure, 145 maximum, 15 minimum
Ps = Gas supply (suction) pressure
The 9/16-18 is a 1/4″ O.D. tubing, high pressure coned and threaded connection.
Stall pressure must not be allowed to exceed outlet pressure rating.
Compression ratio is the minimum required ratio of outlet pressure/supply pressure.
- DAS: Dry Air Spool
- DASR: Dry Air Spool Modification, Pressure Reducing Regulator with Gauge and Relief Valve (For Driving Booster From N2 Gas Bottle)
- TR: Timer Relay (Operator Can Control The Cycles Per Minute)
- NBR: Change Seals to Nitrile Buna Rubber (For Use With CO2)
- O2: Oxygen Cleaning & Modifications (For Use With Oxygen)
- H2: Oxygen Cleaning & Safe Ventilation & Purging Modifications (For Use With Hydrogen)
- SGD: Sour Gas Modification (For Driving With Sour Gas)
- LT: Low Temperature Modification (For Use In Sub Artic Conditions)
- HT: High Temperature Modification For Temperature of 120 °C (For L or LSF Pumps)
- EPOXY: Epoxy Coat Booster (For Offshore Applications)
DLE 5-15-2 Flow Chart
4 Bar Air Drive
6 Bar Air Drive
8 Bar Air Drive
Bundle This Booster As A System
(Contact HPT for a system designed specific for your Application)