DLE75-2-2100 Gas Boosters
Maximator DLE75-2-2100 Gas Booster Double Acting, Double Air Head, Single Stage capable of pressures as high as 30,000 psi.
Technical Data
PRESSURE RATIO | 150:1 | |
COMPRESSION RATIO | 20:1 | |
Min. Supply Pressure (Basic Operation) | 660 | |
Min. Supply Pressure (Maximum Outlet)MAX | 7,500 | |
Max. Supply Pressure | 30,000 | |
Max. Outlet Pressure | 30,000 | |
STALL PRESSURE | 150Pa + Ps | |
Inlet Gas Connection | 1/4″ NPT | |
Outlet Connection | 9/16″-18 UNF | |
Max. Freq | 100 Cycles/min | |
Displacement. per Cycle | 3.05 cubic inches in³ | |
Max. Temperature | 212 F ºF | |
Weight | 51 lb |
- Pressures to 30,000 for most gases and 5,000 for oxygen
- Easy to install and operate
- Compact, lightweight design
- Single or double acting and two stage models
- Double air head available in single and two stage boosters
- No electrical power required
- Requires no lubrication
- Boosters are contaminant free
- Units can be operated in series or parallel
- Variety of pressure and compression ratios available
- High pressure gas testing or process qualification
- Charging of accumulators
- Boosting gas pressures from nitrogen or Oxygen bottles and generators
- Nitrogen injection for molding machines
- Leak detection systems
- pressure autoclaving
- Typical Gases – air, nitrogen, helium, oxygen, carbon dioxide, nitrous oxide, neon, argon, hydrogen, carbon monoxide, methane, ethylene and natural gas
All gas boosters are available with an optional air control unit (-ACP). This package is shown below and consists of an air filter, regulator with gauge, shutoff valve and necessary fittings and hose for plumbing unregulated pilot port
HPT offers a wide variety of other accessories to assist the installation of your Maximator gas booster.
- Gas receivers
- Pressure gauges
- Air pilot pressure switches
- Filters
- High pressure valves, fittings and tubing
- Miscellaneous plumbing components
* = Minimum required for basic operation
** = Minimum required to achieve maximum outlet pressures
Pa = Drive air pressure, 145 maximum, 15 minimum
Ps = Gas supply (suction) pressure
The 9/16-18 is a 1/4″ O.D. tubing, high pressure coned and threaded connection.
Stall pressure must not be allowed to exceed outlet pressure rating.
Compression ratio is the minimum required ratio of outlet pressure/supply pressure.
Air Control Unit (-ACP)
Air pilot pressure switches
Filters
Gas receivers
High pressure valves, fittings and tubing
Miscellaneous plumbing components
Pressure gauges
DLE75-2-2100 Flow Chart
Bundle This Booster As A System
(Contact HPT for a system designed specific for your Application)